# Using the Mikrotik RDS2216

*November 29, 2025* — https://jade.wtf/tech-notes/mikrotik-rds2216-notes/

Tags: Mikrotik, RDS2216, NVMeOF

---


![](/tech-notes/mikrotik-rds2216-notes/garage_cabinet.jpg "Mikrotik RDS2216 (green) partially hidden behind cables from a Dell XR4000r")

I'm using a [Mikrotik RDS2216](https://mikrotik.com/product/rds2216) as a ethernet switch and NVMe-OF storage server for my home Proxmox cluster.
The RDS2216 and Mikrotik RouterOS Storage Edition (ROSE) are relatively new products, so I've run into a few surprises and sharp edges but overall it's working. 

## Configuration Notes
Instructions on how to set up RAID and NVMeOF exports on ROSE are rather spotty so I had to piece together how to get it to work from available docs, on-device tab-completion, and through trial & error. Unfortunately I realized that I forgot to write down how set it up after losing RAID arrays and NVMeOF exports because of the 2025-11 quirk listed below. So, now I'm documenting here 😊

I prefer to manage storage by position-independent attributes, so you'll see `[ find key=value ]` matching in set statements.

### Setting up a drive
```routeros
/disk set [ find serial=S64GNG0X413417 ] comment=tk8s-node1-a self-encryption-password=SuperSecureSecretSentence
```

I set a comment on each drive of volumename-volumeindex where volumeindex a..z indicates the drive's position in the RAID array. I don't bother with the -volumeindex part if the drive isn't going to be part of an array.

All the 7mm U.2 drives I've found support the TCG Opal self-encrypting drive standard, so I always use it so I don't have to worry about physically destroying drives if they fail -- data unreadable[^1] as soon as the drive is separated from the RDS2216 or the RDS2216's config is wiped.

### Setting up a RAID array
```routeros
/disk add type=raid raid-type=1 raid-device-count=2 mount-filesystem=no comment=tk8s-node1
/disk set [ find comment=tk8s-node1-a ] raid-master=[ find comment=tk8s-node1 ]
/disk set [ find comment=tk8s-node1-b ] raid-master=[ find comment=tk8s-node1 ]
```

`raid-type` is set to the RAID level. E.g. 0=stripe, 1=mirror, 5=striping with parity for single-disk failure, 6=striping with parity for double-disk failure.

`raid-device-count` is the number of drives used in the array not including any spares.

We don't specify the slot because RouterOS will automatically pick the next `raid-arrayN`. 
We reduce the risk of changing the wrong RAID config or adding/removing disks from the wrong array by never directly specifying e.g. `slot=raid-array1` and by setting `raid-master` using find instead of a hardcoded value.

We want `raid-role` to correspond  to volumeindex as a=0, b=1, c=2, and so on. If you omit `raid-role` RouterOS will autoincrement, so be sure to add drives in order or specify the correct `raid-role`.

### Sharing a RAID array using NVMeoF

Easy enough, except no access control -- I haven't been able to get `nvme-tcp-server-allow-host-name` to work.
```routeros
/disk set [ find comment=tk8s-node1 ] nvme-tcp-export=yes
```

And test by running `nvme discover` on your Linux host:
```
root@gpc1:/# nvme discover -t tcp -a 10.8.9.1 -s 4420

Discovery Log Number of Records 1, Generation counter 60
=====Discovery Log Entry 0======
trtype:  tcp
adrfam:  ipv4
subtype: nvme subsystem
treq:    not specified, sq flow control disable supported
portid:  4420
trsvcid: 4420
subnqn:  raid-array2
traddr:  10.8.9.1
eflags:  none
sectype: none
```

### QSFP28 DAC breakout to Intel E823-C on Dell XR4000 chassis node won't link at 25G?
Set `fec-mode=fec74`

Example full config line:
```routeros
/interface/ethernet set [ find default-name=qsfp28-2-1 ] advertise=25G-baseCR comment="Server: gpc1 (frontend)" fec-mode=fec74 l2mtu=9100
```

I recently cabled up the 25G ports on the RDS2216 to this same NIC and needed to leave it at auto. Am not sure if this was resolved in a Mikrotik firmware update or if the problem I encountered was specific to using a QSFP28 breakout on the 100G port.

## Quirks, Bugs, Defects, and Surprises

* 2025-11: My RAID arrays disappeared after upgrading to software 7.20.4. I suspect this was caused by improved validation on RAID device naming [in 7.20](https://forum.mikrotik.com/t/v7-20-stable-is-released/265196). Now they are named with key "slot" expecting value of `raid-arrayN` and prior I used a value of my volume name (e.g. `gpc1-util1`) so I could see sensical names on my hosts instead of leaking storage details like `raid-array4`.
* 2026-01: Log messages every few seconds for PSU2 failing and recovering. Started within a month of installation. Replaced PSU2 with a spare and it was fine for a few months before the spare failed as well. Now I'm running on only PSU1. I unplugged PSU2 to stop its fan from ramping up and down constantly.

[^1]: Yes, I know that the data isn't destroyed. It could be recovered if someone knew the secret or if there was a defect in the drive firmware. SED is good enough for my threat model.

---